KYORITSU MODEL 2433


Category: Clamp Meter

Quick Overview:

Tag: #Leakage Clamp Meters 

Share: Messenger


• Frequency Selector Switch to eliminate the effect of harmonics.
• Three AC current ranges:40mA/400mA/400A.
• Resolution 0.01mA.
  • φ40
  • MAX400A
  • Filter
  • PeakHold10ms
 
AC A (50/60Hz) 40/400mA/400A
±1%rdg±5dgt (40/400mA)
±1%rdg±5dgt (0 - 350A)
±2%rdg (350.1 - 399.9A)
AC A (WIDE) 40/400mA/400A
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [20Hz - 1kHz] (40/400mA)
±1%rdg±5dgt [50/60Hz],
±2.5%rdg±10dgt [40Hz - 1kHz] (0 - 350A)
±2%rdg [50/60Hz],
±5%rdg [40Hz - 1kHz] (350.1 - 399.9A)
Maximum circuit voltage 600V AC/DC (between line/neutral)
300V AC/DC (against earth)
Conductor size Ø40mm max.
Frequency response 20Hz - 1kHz (40Hz - 1kHz:400A)
Effect of External Stray Magnetic Field 10mA AC approx. in proximity to a 15mm-dia
conductor carrying 100A AC
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-032
Response Time Approx. 2 seconds
Power source Two R03 or equivalent (DC1.5V) batteries
Dimensions 185(L) × 81(W) × 32(D)mm
Weight 270g approx.
Included Accessories 9097 (Carrying Case)
R03 (1.5V) × 2
Instruction Manual

Product Catalogue


Sorry, Currently No Video Uploaded.
Sorry, Currently No File Uploaded.