KYORITSU KEW 1052


Category: Multimeter

Quick Overview:

Share: Messenger


High Accuracy, High Performance and Reliable Measurements
• 0.09% basic DC accuracy
• Large display with 6,000 counts
• True-RMS Measurements
• True-RMS or MEAN value detection mode can be selected
• Low-pass filter for motor drive measurements
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -10 to 55ºC

Reliable support for data management
• Large data internal memory 1,600 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
*MAX 32,767 data can be transferred.
  • TRUE RMS
  • CAT4 600V
  • DCACV
  • DCACA
  • Resistance
  • Continuitybuzzer
  • Diode
  • Capacitance
  • Frequency
  • Temperature
  • Backlight
  • DATAHOLD
  • MAX/MIN/AVG
  • Relative
  • Filter
  • USB
  • AutoPowerOff
 
Detection mode MEAN/RMS (switch)
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ [600mV/60/600/1000V], 11MΩ [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
AC V [MEAN] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10MΩ<200pF [600mV], 11MΩ<50pF [6V],
10MΩ<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0Ω (The buzzer turns on for resistances lower than 50±30Ω)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
Option
Description Model Specification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
USB Communication set 8241 USB adaptor + USB cable + DMM Software
DMM Printer full set 8249 8243+8246+8248
  Printer Communication set 8243 Printer Adapter + RS232 cable
Printer 8246 Printer + Thermal paper (1 roll)
AC adapter for printer [EU] 8248A AC230V±10%
Thermal paper for printer 8247 10 rolls
Carrying case 9154 for the main unit with testi leads and communication cable
Thermocouple Type K Specification
Description Model Specification
Temperature probes 8405 -40ºC - 500ºC
(Surface type, Point material: Ceramic)
8406 -40ºC - 500ºC (Surface type)
8407 -40ºC - 700ºC (Liquid, Semi-solid)
8408 -40ºC - 600ºC (Air, Gas)

Product Catalogue


Sorry, Currently No Video Uploaded.
Sorry, Currently No File Uploaded.

KYORITSU KEW 1052


Please Leave Your Product Enquiry Here. We will Get Back To You Soon.

Product Specifications

  • Product SKU : -
  • Weight (GRAM) : -
  • Dimension : -


Locate Us