KYORITSU KEW 1062


Category: Multimeter

Quick Overview:

Share: Messenger


High Accuracy, High Performance and Reliable Measurements
• 0.02% basic DC accuracy
• Large display with 50,000 counts
• Dual display for double indication for AC and DC, V and Hz, etc.
• True-RMS Measurements AC and AC+DC
• Wide AC Frequency bandwidth from 10Hz to 100kHz
• True-RMS or MEAN value detection mode can be selected
• Fast Peak Hold response time of 250µs
• Low-pass filter for motor drive measurements
• Low Power Ω for resistance measurements on sensible electronic circuits by a low and safe test current
• User calibration function

Safety design for industrial use
• Complies with IEC 61010-1 CAT IV 600V, CAT III 1000V
• Terminal shutter to prevent incorrect test leads' insertion in current terminals
• Very wide operating temperature range from -20 to 55ºC

Reliable support for data management
• Large data internal memory
KEW 1062: 10,000 data (logging), 100 data (manual)
• Download data and Live Monitoring on a PC via the USB interface
(Option for USB Communication set)
* MAX 32,767 data can be transferred.
  • TRUE RMS
  • CAT4 600V
  • DCACV
  • DCACA
  • DC+AC
  • Resistance
  • LowPowerΩ
  • Continuitybuzzer
  • Diode
  • Capacitance
  • Frequency
  • DUTY
  • Temperature
  • Decibel
  • Backlight
  • DATAHOLD
  • Peakhold
  • MAX/MIN/AVG
  • Relative
  • Filter
  • USB
  • AutoPowerOff
 
Detection mode MEAN/RMS (switch)
DC V 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
(Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V])
±0.02%rdg±2dgt (Basic accuracy)
AC V [RMS] 50.000/500.00mV/5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V])
±0.4%rdg±30dgt (Basic accuracy)
AC V [MEAN] 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V
(Input impedance:11MΩ<50pF [50/500mV/5V],10MΩ<50pF [50/500/1000V])
±1%rdg±30dgt (Basic accuracy)
DCV+ACV 5.0000/50.000/500.00/1000.0V
(Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V])
±0.5%rdg±10dgt (Basic accuracy)
DC A 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
±0.2%rdg±5dgt (Basic accuracy)
AC A [RMS] 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
±0.75%rdg±20dgt (Basic accuracy)
AC A [MEAN] 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A
±1.5%rdg±20dgt (Basic accuracy)
DCA+ACA 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
±1%rdg±10dgt (Basic accuracy)
Ω 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ
±0.05%rdg±2dgt (Basic accuracy)
LowPower-Ω 5.000/50.00/500.0kΩ/5.000MΩ
±0.2%rdg±3dgt (Basic accuracy)
Continuity buzzer 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω)
Diode test 2.4000V ±1%rdg±2dgt
Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current)
Capacitance 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF
±1%rdg±5dgt (Basic accuracy)
Frequency 2.000 - 9.999/9.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
DUTY 10 - 90% ±1%rdg
Temperature -200 - 1372ºC ±1%rdg±1.5ºC
-328 - 2501.6ºF ±1%rdg±2.0ºF
(with the use of K-type Temperature probe)
Measurement functions DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω
Other functions Data Hold (D/H), Auto Hold (A/H), Peak Hold (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)
Option
Description Model Specification
Crocodile clip test lead 7234 CAT IV 600V, CAT III 1000V
AC/DC Clamp Sensor 8115 AC 130A / DC 180A
Clamp sensor 8121 AC 100A
8122 AC 500A
8123 AC 1000A
8146 AC 30A
8147 AC 70A
8148 AC 100A
Banana Ø4mm Adjuster Plug 7146 length:190mm
USB Communication set 8241 USB adaptor + USB cable + DMM Software
DMM Printer full set 8249 8243+8246+8248
  Printer Communication set 8243 Printer Adapter + RS232 cable
Printer 8246 Printer + Thermal paper (1 roll)
AC adapter for printer [EU] 8248A AC230V±10%
Thermal paper for printer 8247 10 rolls
Carrying case 9154 for the main unit with testi leads and communication cable
Thermocouple Type K Specification
Description Model Specification
Temperature probes 8405 -40ºC - 500ºC
(Surface type, Point material: Ceramic)
8406 -40ºC - 500ºC (Surface type)
8407 -40ºC - 700ºC (Liquid, Semi-solid)
8408 -40ºC - 600ºC (Air, Gas)

Product Catalogue


Sorry, Currently No Video Uploaded.